Long-term efficacy and safety of Control-IQ technology in younger children with type 1 diabetes in Italy (2020-2023): a longitudinal multicentre real-world study.
Valentino Cherubini, Roberto Franceschi, Andrea Fargalli, Marta Bassi, Riccardo Bonfanti et al. ·
Summary
Written by AI, not yet AICS's view · claude-haiku-4-5-20251001This study evaluated the long-term effectiveness and safety of Control-IQ automated insulin delivery technology in 253 Italian children with type 1 diabetes aged 0.5-10 years over 18 months. Children in both age groups (0.5-5 years and 6-10 years) showed significant improvements in blood sugar control within the first six months, which were then maintained. Severe adverse events were rare, with no episodes of severe low blood sugar in younger children and only one case in older children.
Key points
- Time in target range (TIR) increased by 5.45% from baseline to 6 months in the overall group and remained stable through 18 months
- No statistically significant differences in glycemic control trajectories between younger (0.5-5 years) and older (6-10 years) children
- No episodes of severe hypoglycemia occurred in children aged 0.5-5 years; only one episode in the 6-10-year group
- Children with parents having higher education levels achieved significantly greater time in target range
- Only one case of diabetic ketoacidosis (DKA) occurred in a younger child during the observation period
Limitations
This is an observational real-world study without a comparison group, so the improvements may be partially attributable to increased parental engagement and monitoring rather than the technology alone. The study was conducted only in Italy and may not be generalizable to other healthcare contexts or populations.
Abstract
BACKGROUND: Automated insulin delivery (AID) systems have demonstrated significant improvements in glycemic control in children and adults with type 1 diabetes, but long-term real-world data in preschool-aged children remain limited, particularly in Europe, where Control-IQ is not approved for children under 6 years. This study aimed to evaluate the long-term effectiveness and safety of the t:slim X2 insulin pump with Control-IQ technology in children aged 0.5-5 years compared with those aged 6-10 years in a real-world multicenter Italian cohort. METHODS: In this longitudinal, observational study conducted from 2020 to 2023, data were collected from 32 Italian centers on children <11 years diagnosed with type 1 diabetes for at least six months and using the t:slim X2 with Control-IQ technology (CIQ). Participants were grouped into 0.5-5 years or 6-10 years at CIQ initiation. Primary endpoints were the percentage of time spent in range (TIR, 70-180 mg/dL) and in tight range (TITR, 70-140 mg/dL) in the two age groups, evaluated according to children's demographic, socioeconomic, and clinical characteristics using mixed-effects models for repeated measures. FINDINGS: We evaluated 253 children with 18-month follow-up, 131 into the 0.5-5-year group and 122 in the 6-10-year group. In the 0.5-5-year group, TIR and TITR increased significantly from baseline to 6 months and were then maintained through 18 months. In the 6-10-year group, similar improvements were observed, with no statistically significant differences between age groups in the TIR or TITR trajectories. In the adjusted mixed-effects models, TIR increased from baseline to 6 months by 5.45% (95% CI 3.78-7.11) and TITR increased by 5.56% (95% CI 3.60-7.51), with stabilization thereafter. Children of parents with a high level of education had a significantly greater mean TIR. A longer interval between T1D diagnosis and CIQ initiation was associated with a lower mean TITR (-1.21%, 95% CI -2.32 to -0.10). During observation, there were no episodes of severe hypoglycemia in younger children and only one episode in a 6-10-year-old. One episode of DKA occurred after the start of CIQ in a younger child. INTERPRETATION: CIQ was associated with sustained improvements in glycemic outcomes, especially within the first six months. Adverse events were rare. These findings support potential supervised off-label use in young children. FUNDING: No specific funds were received for this study.
Findings the Hub has extracted
Each claim below is labelled by its type of design and links back to this report.
- Intervention
- t:slim X2 insulin pump with Control-IQ automated insulin delivery technology
- Population
- 253 children with type 1 diabetes aged 0.5-10 years (131 aged 0.5-5 years, 122 aged 6-10 years) from 32 Italian diabetes centers
Key finding
Time in range increased by 5.45% (95% CI 3.78-7.11) from baseline to 6 months with stabilization thereafter